Green Tech Tools
  Shopping Cart Shopping Cart - 0 item(s)
 Speciality Tools
 AEMC
 Alnor Balometers
 Bacharach
 Cool Machines Fiber Blowers
 David White Instruments
 Fluke Test Equipment
 Green Tech Insulation Blowers
 Miller Fall Protection
 Retrotec Blower Door Systems
 Testo Test and Measurement
 Tramex Mositure Meters
 TSI Flow Hoods
 UEI Instruments
 

Home > Retrotec Blower Door Systems
Retrotec R31 Duct Testing Blower System
Part Number 1640
Retrotec R31 Duct Testing Blower System
Email this page to a friend Email this page to a friend
Review this item Review this item
Price
Your Price:  
$2,239.65
Quantity
Description

Retrotec R31 Economy Duct Testing Duct Blower system with Manual Control

For measuring duct leakage in residential & light commercial buildings.

Retrotec Model R31 consists of a Duc-Tester Module, a DM-2 Digital gauge and a 12 foot flex-duct with flanges for mounting on the return register. Case for DM-2A and grill mask dispenser not included.

New Home or Utility Standards

The Retrotec Duc-Tester is designed specifically to measure residential duct leakage. It can then be used to locate duct leaks and to measure the results of duct sealing. Use the Model R31 Duc-Tester to verify duct leakage for compliance with codes such as Title 24 in California. The typical 5 Ton air-conditioning system must have 120 cfm of leakage or less to pass California standards. The R31 will easily test any residential system because it will create 600 cfm which is 5 times more than that.

Retrotec Model R31 Specifications

Fan Flow (accuracy +/- 2.5 % with Retrotec DM-2 or Auto Correct software)

Maximum Flow in Free Air: 750 CFM 353 l/s 1273 m3/h
Maximum Flow at 25 Pascal with flex attached to a register: 530 CFM 250 l/s 901 m3/h
Minimum Flow at 25 Pascal test pressure with flex attached: 5 CFM 2.36 l/s 8.49 m3/h
Dimensions of Fan unit 14 × 14 × 12 in (35 × 35 × 30 cm)
Fan Motor: EBM backward curved impeller. 120V 2a or 240V 1a
Dimensions of Flex Duct 10” diameter. 15” to 10’ in length.
Dimensions of Carrying Case 25” × 14” × 15”

Calibration meets: Canadian CGSB-149.1-2002 & SuperE, USA ASTM E 779 – 03, European EN 13829 & CEN, UK TM-23 Energy Standards. NFPA 2001- 01, ISO 14520 and fire standards.

Specifications subject to change without notice. Infiltrometer is a registered trademark of Retrotec. Two (2) years parts and labor on fan unit

Operation

The Duc-Tester will pressurize or depressurize a duct system (with the air handler off) from the main return grille (or blower access opening). The rest of the register openings are taped shut. Duct pressure is measured by static probes in the supply ducts. Airflow is determined by reading flow directly from the DM-2. No computer is required. Setup, taping the registers and getting results takes less than 20 minutes in most homes. The Duc-Tester can also be used in conjunction with a blower door to neutralize duct leaks to indoors to that only duct leakage to outdoors is measured. 


Product Information
R31 Specifications R31 Specifications
  Blower Door Testing Blower Door Testing
  Building Pressurization Building Pressurization
  Blower Doors and Duct Blasters Blower Doors and Duct Blasters
  Using Blower Door Data Using Blower Door Data


Related Items
Nikro 860757-22050 860757 22050 5HP 220V/50Hz 175 PSI Portable Electric Compressor
Nikro 860757-22050 860757 22050 5HP 220V/50Hz 175 PSI Portable Electric Compressor
Average Rating 0 Review(s)
Your Price: Contact for Price (877) 801-5693
Nikro HP20GAS #4 Gasoline Powered Air Duct Cleaning Package
Nikro HP20GAS #4 Gasoline Powered Air Duct Cleaning Package
Average Rating 0 Review(s)
Your Price: Contact for Price (877) 801-5693
Nikro UR800 UR 800 115V 60Hz Upright Portable Air Scrubber
Nikro UR800 UR 800 115V 60Hz Upright Portable Air Scrubber
Average Rating 0 Review(s)
Your Price: $985.00

Green Tech Tools Affiliate Program