Kigaz 100 Specifications
GAS
Ambient CO max
CO flue gas
Interchangeablesensors : O2 and CO compensated H2
Excess air Losses
Efficiency > 100 percent
PRESSURE
Differential pressure measurement
Draft measurement
TEMP.
Ambient temp.
Flue gas temp.
Delta Temp.
DHW temp.
Dew point temp.
OTHER FUNCTIONS
15 programmed combustibles
Adding 5 combustibles by the user
Automatic measurements
Opacity index
External water trap
Combustibles : Sahara/Fos-sur-Mer Natural Gas, (Groningen) Natural Gas, Russia - North Sea Nat. Gas, Butane , LPG, Propane, Heavy Oil, Light Oil, Bio fuel 5 percent, Hard coal, Coke gas, Bituminous coal, Wood 20 percent, Wood-chip 21 percent, Pellet 8 percent
Kigaz 100 Measuring Range
Parameter
Sensor
Measuring range
Resolution
Accuracy*
T90 response time
O2
Electro-chemical
from 0 percent - 21 percent
0.1 percent vol.
+/-0.2 percent vol.
30 sec.
CO(with H2Compensation)
K thermocouple
from -100 - +1250 deg. C
0.1 deg. C
+/-1 deg. C
45 sec.
Internal NTC
From -20 - +120 deg. C
Pt100 (1/3 Din external probe)
From -50 - +250 deg. C
+/-0.3 percent of the measured value +/-0.25 deg. C
Calculated**
From 0 - +99 deg. Ctd
TcK (external probe)
From -200 - +1300 deg. C
Differential pressure Draft
Semiconductor
From -20 000 - +20 000 Pa
1 Pa
From -20 000 - -751 Pa : +/-(-0.5 percent of measured value +4.5 Pa)From 750 - -61 Pa : +/-(-0.9 percent of measured value +1.5 Pa) From -60 - 60 Pa : +/-2 PaFrom 61 - 750 Pa : +/-(0.9 percent of measured value +1.5 Pa)From 751 - 20 000 Pa : +/-(0.5 percent of measured value + 4.5 Pa)
Losses
From 0 - 100 percent
0.1 percent
Excess air (Λ)
From 1 - 9.99
0.01
Lower efficiency (ηs)
Higher efficiency (ηt) (condensing)
From 0 - 120 percent
External instrument
From 0 - 9
*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.**Calculation is made based on the measured values by the analyzer.